Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Anesthesiol ; 23(1): 180, 2023 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-37231335

RESUMO

BACKGROUND: The new noninvasive Vitalstream (VS) continuous physiological monitor (Caretaker Medical LLC, Charlottesville, Virginia), allows continuous cardiac output by a low pump-inflated, finger cuff that pneumatically couples arterial pulsations via a pressure line to a pressure sensor for detection and analysis. Physiological data are communicated wirelessly to a tablet-based user interface via Bluetooth or Wi-Fi. We evaluated its performance against thermodilution cardiac output in patients undergoing cardiac surgery. METHODS: We compared the agreement between thermodilution cardiac output to that obtained by the continuous noninvasive system during cardiac surgery pre and post-cardiac bypass. Thermodilution cardiac output was performed routinely when clinically indicated by an iced saline cold injectate system. All comparisons between VS and TD/CCO data were post-processed. In order to match the VS CO readings to the averaged discrete TD bolus data, the averaged CO readings of the ten seconds of VS CO data points prior to a sequence of TD bolus injections was matched. Time alignment was based on the medical record time and the VS time-stamped data points. The accuracy against reference TD measurements was assessed via Bland-Altman analysis of the CO values and standard concordance analysis of the ΔCO values (with a 15% exclusion zone). RESULTS: Analysis of the data compared the accuracy of the matched measurement pairs of VS and TD/CCO VS absolute CO values with and without initial calibration to the discrete TD CO values, as well as the trending ability, i.e., ΔCO values of the VS physiological monitor compared to those of the reference. The results were comparable with other non-invasive as well as invasive technologies and Bland-Altman analyses showed high agreement between devices in a diverse patient population. The results are significant regarding the goal of expanding access to effective, wireless and readily implemented fluid management monitoring tools to hospital sections previously not covered because of the limitations of traditional technologies. CONCLUSION: This study demonstrated that the agreement between the VS CO and TD CO was clinically acceptable with a percent error (PE) of 34.5 to 38% with and without external calibration. The threshold for an acceptable agreement between the VS and TD was considered to be below 40% which is below the threshold recommended by others.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Humanos , Débito Cardíaco/fisiologia , Ponte de Artéria Coronária , Dedos , Artérias , Termodiluição/métodos , Reprodutibilidade dos Testes
2.
BMC Anesthesiol ; 20(1): 98, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-32357833

RESUMO

BACKGROUND: Neural networks are increasingly used to assess physiological processes or pathologies, as well as to predict the increased likelihood of an impending medical crisis, such as hypotension. METHOD: We compared the capabilities of a single hidden layer neural network of 12 nodes to those of a discrete-feature discrimination approach with the goal being to predict the likelihood of a given patient developing significant hypotension under spinal anesthesia when undergoing a Cesarean section (C/S). Physiological input information was derived from a non-invasive blood pressure device (Caretaker [CT]) that utilizes a finger cuff to measure blood pressure and other hemodynamic parameters via pulse contour analysis. Receiver-operator-curve/area-under-curve analyses were used to compare performance. RESULTS: The results presented here suggest that a neural network approach (Area Under Curve [AUC] = 0.89 [p < 0.001]), at least at the implementation level of a clinically relevant prediction algorithm, may be superior to a discrete feature quantification approach (AUC = 0.87 [p < 0.001]), providing implicit access to a plurality of features and combinations thereof. In addition, the expansion of the approach to include the submission of other physiological data signals, such as heart rate variability, to the network can be readily envisioned. CONCLUSION: This pilot study has demonstrated that increased coherence in Arterial Stiffness (AS) variability obtained from the pulse wave analysis of a continuous non-invasive blood pressure device appears to be an effective predictor of hypotension after spinal anesthesia in the obstetrics population undergoing C/S. This allowed us to predict specific dosing thresholds of phenylephrine required to maintain systolic blood pressure above 90 mmHg.


Assuntos
Raquianestesia/métodos , Cesárea/métodos , Hipotensão/etiologia , Vasoconstritores/administração & dosagem , Adulto , Anestesia Obstétrica/efeitos adversos , Anestesia Obstétrica/métodos , Raquianestesia/efeitos adversos , Pressão Sanguínea/efeitos dos fármacos , Relação Dose-Resposta a Droga , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Hipotensão/epidemiologia , Redes Neurais de Computação , Fenilefrina/administração & dosagem , Projetos Piloto , Gravidez , Análise de Onda de Pulso , Adulto Jovem
3.
J Agric Food Chem ; 52(21): 6433-42, 2004 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-15479003

RESUMO

Extracts from wild blueberry (Vaccinium angustifolium Ait.) were separated into proanthocyanidin-rich fractions using liquid vacuum and open column chromatography on Toyopearl and Sephadex LH-20, respectively. Fractions were characterized using analytical tools including mass spectrometry and NMR spectroscopy; fraction composition was correlated with bioactivity using antiproliferation and antiadhesion in vitro assays. There was a significant positive correlation between proanthocyanidin content of different fractions and biological activity in both the antiproliferation and antiadhesion assays. Two fractions containing primarily 4-->8-linked oligomeric proanthocyanidins with average degrees of polymerization (DPn) of 3.25 and 5.65 inhibited adhesion of Escherichia coli responsible for urinary tract infections. Only the fraction with a DPn of 5.65 had significant antiproliferation activity against human prostate and mouse liver cancer cell lines. These findings suggest both antiadhesion and antiproliferation activity are associated with high molecular weight proanthocyanidin oligomers found in wild blueberry fruits.


Assuntos
Aderência Bacteriana/efeitos dos fármacos , Divisão Celular/efeitos dos fármacos , Proantocianidinas/isolamento & purificação , Proantocianidinas/farmacologia , Vaccinium/química , Animais , Escherichia coli , Humanos , Neoplasias Hepáticas Experimentais/patologia , Espectroscopia de Ressonância Magnética , Masculino , Espectrometria de Massas , Camundongos , Polímeros/química , Proantocianidinas/química , Neoplasias da Próstata/patologia , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Relação Estrutura-Atividade , Células Tumorais Cultivadas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...